Out of stock!
EMI Payment Options
Product Description
Specification
Output |
|
Output power capacity | 660Watts / 1.1 kVA |
Max Configurable Power (Watts) | 660Watts / 1.1 kVA |
Nominal Output Voltage | 230V |
Topology | Line Interactive |
Maximum Output Current | 10 |
Input |
|
Nominal Input Voltage |
230V |
Input frequency |
47 - 63 Hz |
Input Connections |
Indian/South African BS 546A |
Cord Length |
1.48meters |
Input voltage range for main operations |
175 - 295V |
Input voltage adjustable range for mains operation |
160 - 286V |
Number of Power Cords |
1 |
Batteries & Runtime |
|
Battery type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
Included Battery Modules |
1 |
Typical recharge time |
10hour(s) |
Replacement Battery |
APCRBC113 |
Expected Battery Life (years) |
2 - 4 |
RBC Quantity |
1 |
Communications & Management |
|
Control panel |
LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Audible Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays |
Surge Protection and Filtering |
|
Surge energy rating |
441Joules |
Data Line Protection |
Analog phone line for phone/fax/modem/DSL (RJ-11 connector) |
Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Physical |
|
Net Weight |
11.0KG |
Environmental |
|
Operating Temperature |
0 - 40 °C |
Operating Relative Humidity |
0 - 95 % |
Operating Elevation |
0-3000meters |
Storage Temperature |
-5 - 45 °C |
Storage Relative Humidity |
0 - 95 % |
Storage Elevation |
0-15000meters |
Audible noise at 1 meter from surface of unit |
45.0dBA |
Online thermal dissipation |
180.0BTU/hr |
Warranty |
2 Years |
Note |
***Features, Price and Specifications are subject to change without notice. |
Features
APC Back-UPS 1100, 230V, BS546A, without auto shutdown software, India
Audible alarms
Provides notification of changing utility power and UPS power conditions
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
LED status indicators
Quickly understand unit and power status with visual indicators.
Replace Battery LED
An external Replace Battery LED informs the end-user that the battery needs to be replaced.
Resettable circuit breakers
Enables a quick recovery from overload events.